schneider-electric ecostruxure control expert vulnerabilities and exploits
(subscribe to this query)
NA
CVE-2023-1049
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local filesystem into the HMI.
Schneider-electric Ecostruxure Operator Terminal Expert 3.3
Schneider-electric Ecostruxure Operator Terminal Expert
Schneider-electric Pro-face Blue 3.3
Schneider-electric Pro-face Blue
NA
CVE-2023-27976
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above)
Schneider-electric Ecostruxure Control Expert
NA
CVE-2023-1548
A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above)
Schneider-electric Ecostruxure Control Expert
NA
CVE-2022-45789
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process ...
Schneider-electric Ecostruxure Control Expert
Schneider-electric Ecostruxure Process Expert
Schneider-electric Modicon M340 Bmxp341000 Firmware
Schneider-electric Modicon M340 Bmxp342000 Firmware
Schneider-electric Modicon M340 Bmxp342010 Firmware -
Schneider-electric Modicon M340 Bmxp3420102 Firmware
Schneider-electric Modicon M340 Bmxp342020 Firmware
Schneider-electric Modicon M340 Bmxp342020h Firmware
Schneider-electric Modicon M340 Bmxp342030 Firmware
Schneider-electric Modicon M340 Bmxp3420302 Firmware
Schneider-electric Modicon M340 Bmxp3420302h Firmware
Schneider-electric Modicon M340 Bmxp342030h Firmware
Schneider-electric Modicon M580 Bmep581020 Firmware
Schneider-electric Modicon M580 Bmep581020h Firmware
Schneider-electric Modicon M580 Bmep582020 Firmware
Schneider-electric Modicon M580 Bmep582020h Firmware
Schneider-electric Modicon M580 Bmep582040 Firmware
Schneider-electric Modicon M580 Bmep582040h Firmware
Schneider-electric Modicon M580 Bmep582040s Firmware
Schneider-electric Modicon M580 Bmep583020 Firmware
Schneider-electric Modicon M580 Bmep583040 Firmware
Schneider-electric Modicon M580 Bmep584020 Firmware
NA
CVE-2022-45788
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxur...
Schneider-electric Ecostruxure Control Expert
Schneider-electric Ecostruxure Process Expert
Schneider-electric Modicon M340 Bmxp341000 Firmware -
Schneider-electric Modicon M340 Bmxp342000 Firmware -
Schneider-electric Modicon M340 Bmxp342010 Firmware -
Schneider-electric Modicon M340 Bmxp3420102 Firmware -
Schneider-electric Modicon M340 Bmxp342020 Firmware -
Schneider-electric Modicon M340 Bmxp342020h Firmware -
Schneider-electric Modicon M340 Bmxp342030 Firmware -
Schneider-electric Modicon M340 Bmxp3420302 Firmware -
Schneider-electric Modicon M340 Bmxp3420302h Firmware -
Schneider-electric Modicon M340 Bmxp342030h Firmware -
Schneider-electric Modicon M580 Bmeh582040 Firmware -
Schneider-electric Modicon M580 Bmeh582040c Firmware -
Schneider-electric Modicon M580 Bmeh582040s Firmware -
Schneider-electric Modicon M580 Bmeh584040 Firmware -
Schneider-electric Modicon M580 Bmeh584040c Firmware -
Schneider-electric Modicon M580 Bmeh584040s Firmware -
Schneider-electric Modicon M580 Bmeh586040 Firmware -
Schneider-electric Modicon M580 Bmeh586040c Firmware -
Schneider-electric Modicon M580 Bmeh586040s Firmware -
Schneider-electric Modicon M580 Bmep581020 Firmware -
NA
CVE-2022-37302
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior).
Schneider-electric Ecostruxure Control Expert
Schneider-electric Ecostruxure Control Expert 15.1
NA
CVE-2022-37300
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (fo...
Schneider-electric Ecostruxure Process Expert
Schneider-electric Ecostruxure Control Expert
Schneider-electric Modicon M340 Bmxp341000 Firmware
Schneider-electric Modicon M340 Bmxp342000 Firmware
Schneider-electric Modicon M340 Bmxp342010 Firmware
Schneider-electric Modicon M340 Bmxp3420102 Firmware
Schneider-electric Modicon M340 Bmxp342020 Firmware
Schneider-electric Modicon M340 Bmxp342020h Firmware
Schneider-electric Modicon M340 Bmxp342030 Firmware
Schneider-electric Modicon M340 Bmxp3420302 Firmware
Schneider-electric Modicon M340 Bmxp3420302h Firmware
Schneider-electric Modicon M340 Bmxp342030h Firmware
Schneider-electric Modicon M580 Bmeh582040 Firmware
Schneider-electric Modicon M580 Bmeh582040c Firmware
Schneider-electric Modicon M580 Bmeh582040s Firmware
Schneider-electric Modicon M580 Bmeh584040 Firmware
Schneider-electric Modicon M580 Bmeh584040c Firmware
Schneider-electric Modicon M580 Bmeh584040s Firmware
Schneider-electric Modicon M580 Bmeh586040 Firmware
Schneider-electric Modicon M580 Bmeh586040c Firmware
Schneider-electric Modicon M580 Bmeh586040s Firmware
Schneider-electric Modicon M580 Bmep581020 Firmware
7.5
CVSSv2
CVE-2022-26507
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21...
Att Xmill 0.7
Schneider-electric Ecostruxure Process Expert
Schneider-electric Ecostruxure Control Expert
Schneider-electric Ecostruxure Control Expert 15.1
Schneider-electric Remoteconnect -
9.3
CVSSv2
CVE-2021-22797
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project ...
Schneider-electric Ecostruxure Control Expert
Schneider-electric Ecostruxure Process Expert
Schneider-electric Remoteconnect -
4.3
CVSSv2
CVE-2022-24323
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Aff...
Schneider-electric Ecostruxure Control Expert
Schneider-electric Ecostruxure Control Expert 15.0
Schneider-electric Ecostruxure Process Expert
CVSSv2
CVSSv2
CVSSv3
VMScore
Recommendations:
firmware
CVE-2023-52866
CVE-2024-4367
CVE-2024-1721
CVE-2023-34992
XML injection
CVE-2023-52817
SQL
CVE-2023-52855
Vulnerability Notification Service